SHDA100 Series


SHDA100 SERIES


100W Desktop Power Supply for Medical Equipment



  • Wide Input Voltage 90 to 260 VAC, 47 to 63Hz, Active Power Factor Correction
  • IEC-320-C14 input inlet
  • Output Voltage Available From 11VDC Thru 48VDC
  • Single Output, Class I Insulation
  • Input Surge Current, Over Voltage, Over Load and Output Voltage protection.
  • Energy Star 2.0, CEC V, and RoHS Compliance


2 Year Warranty


Approvals: 


Single Output

Product Number

Output Voltage

Max. Output Current

Total Regulation

Maximum

Output Power

SHDA100-S05

11 ~ 13 VDC

9.09 ~ 7.69 A

5%

100W

SHDA100-S06

13 ~ 16 VDC

7.69 ~ 6.25 A

4%

100W

SHDA100-S07

16 ~ 21 VDC

6.25 ~ 4.76 A

4%

100W

SHDA100-S08

21 ~ 27 VDC

4.76 ~ 3.70 A

4%

100W

SHDA100-S09

27 ~33 VDC

3.70 ~ 3.03 A

3%

100W

SHDA100-S11

40 ~ 48 VDC

2.50 ~ 2.08 A

3%

100W

 Total Regulation is guaranteed by below configuration

(S05: AWG16/2C/4FT output cable)(S06, S07: AWG18/2C/4FT output cable)(S08~S10: AWG18/2C/6FT output cable)


Electrical Characteristics

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Input Voltage

Operating Voltage

90


260

VAC

Input Frequency


47


63

Hz

Power Factor Correction

Io=Full load, Vin=230 VAC

0.95


1


Output Power Range

Vin= 90 to 264 VAC

0


100

W

Input Current (Low Line)

Io=Full load, Vin=115 VAC



1.35

A

Input Current (High Line)

Io=Full load, Vin= 230 VAC



0.5

A

Low Line Inrush Current

Io=Full load, 25°C, Cool start,

Vin=115VAC


44

50

A

High Line Inrush Current

Io=Full load, 25°C, Cool start,

Vin=230 VAC


85

100

A

Efficiency

Io=Full Load, Vin=230VAC

85

87

90

%

Line Regulation

Io=Full Load


0.5

1

%

Load Regulation

Vin=230VAC


3

5

%

Over Voltage Protection


112


132

%

Over Current Protection


110


150

%

Transient Response

Io=Full Load to Half Load, Vin=100VAC



4

mS

Hold-Up Time

Io=Full Load, Vin=110VAC

12



mS

Start Up Time

Io=Full Load,        Vin=100VAC

0.3

1.5

2

S

Ripple & Noise (Peak to Peak)

Full Load, Vin=90VAC


0.5

1

%

Safety Ground Leakage Current

Io= Full Load, Vin=240VAC


0.15

0.25

mA

No-Load Power Consumption

No load, Vin=240VAC



0.5

W

Temperature Coefficient

All output

-0.04


0.04

%/°C



Conditions

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Operating Temperature


0


70

°C

Storage Temperature


-40


85

°C

Relative Humidity


5


95

%

Operation temperature at 25??/span>, calculated per MIL-HDBK-217F 

0.1



MHrs

Derate linearly from 100% load at 50°C to 50% load at 70°C


Approvals and Compliances

Parameter

Test Conditions

Min.

Unit

Dielectric Withstanding Voltage for Primary to secondary

Primary to secondary

5656

VDC

Dielectric Withstanding Voltage for Primary to Ground

Primary to ground

2828

VDC

Isolation Resistance

Test Voltage = 500VDC

50

EMI requirements for CISPR-11

Vin=220VAC

B

CLASS

EMI requirements for FCC PART-18

Vin=110VAC

B

CLASS

Safety UL/c-UL, TUV/T-mark, FCC, CE,  CB

UL 60601-1, EN 60601-1, IEC 60601-1

n/a

n/a

Environmental Compliance

RoHS, Energy Star 2.0, CEC Level V




Mechanical and PIN out

       

Note:

  1. Dimensions are shown in mm & inch
  2. Weight: approx. 460-800g
               (Exclude the input cord)
  3. Optional output connector.




Mepos Electronics Ltd.
Headquarters
6F, No. 80 Minzu 1st Rd., Sanmin Dist.,
Kaohsiung City 807, Taiwan, ROC
North America Office
5389 Lane Street, Unit #200, Burnaby, BC, Canada V5H 2H4
Online Inquiry

Copyright © Mepos Electronics Ltd. 2005-2009 All Rights Reserved. Terms & Conditions Forms