STUA250 SERIES |
|
250W U-Bracket Power Supply for I.T. Equipment |
|
|
|
|
|
2 Year Warranty |
|
Approvals: |
|
Single Output |
|||||
|
Product Number |
Output Voltage |
Max. Output Current |
Total Regulation |
Maximum Output Power |
|
|
STUA250-S05 |
12 VDC |
18.33 A |
5% |
220W |
|
|
STUA250-S08 |
24 VDC |
10.42 A |
3% |
250W |
|
|
STUA250-S11 |
48 VDC |
5.21 A |
2% |
250W |
|
|
Electrical Characteristics |
|||||
|
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
|
Input Voltage |
Operating Voltage |
100 |
|
240 |
VAC |
|
Input Frequency |
|
47 |
|
63 |
Hz |
|
Power Factor Correction |
Io=Full load, Vin=90~260VAC |
0.95 |
0.97 |
1.00 |
|
|
Output Power Range |
Vin= 90 to 264 VA C |
0 |
|
250 |
W |
|
Input Current (Low Line) |
Io=Full load, Vin=115 VAC |
|
|
3.3 |
A |
|
Input Current (High Line) |
Io=Full load, Vin= 230 VAC |
|
|
1.23 |
A |
|
Low Line Inrush Current |
Io=Full load, 25°C, Cool start, Vin=115VAC |
|
12 |
15 |
A |
|
High Line Inrush Current |
Io=Full load, 25°C, Cool start, Vin=230VAC |
|
25 |
30 |
A |
|
Efficiency |
Io=Full Load, Vin=230VAC |
89 |
91 |
93 |
% |
|
Line Regulation |
Io=Full Load |
|
0.5 |
1 |
% |
|
Load Regulation |
Vin=230VAC |
|
3 |
5 |
% |
|
Over Voltage Protection |
|
112 |
|
132 |
% |
|
Over Current Protection |
|
110 |
|
150 |
% |
|
Transient Response |
Io=Full Load to Half Load, Vin=100VAC |
|
|
4 |
mS |
|
Hold-Up Time |
Io=Full Load, Vin=110VAC |
20 |
|
|
mS |
|
Start Up Time |
Io=Full Load, Vin=100VAC |
0.3 |
1 |
2 |
S |
|
Ripple & Noise (Peak to Peak) |
Full Load, Vin=90VAC |
|
0.5 |
1 |
% |
|
Safety Ground Leakage Current |
Io= Full Load, Vin=240VAC/60Hz |
|
0.5 |
0.75 |
mA |
|
Temperature Coefficient |
All output |
-0.04 |
|
0.04 |
%/°C |
|
|
|||||
|
Conditions |
|||||
|
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
|
Operating Temperature |
|
0 |
|
70 |
°C |
|
Storage Temperature |
|
-40 |
|
85 |
°C |
|
Relative Humidity |
|
5 |
|
95 |
% |
|
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F |
100 |
|
|
K Hrs |
|
|
De-rate linearly from 100% load at 50°C to 50% load at 70°C |
|||||
|
Approvals and Compliance |
|||
|
Parameter |
Test Conditions |
Min. |
Unit |
|
Dielectric Withstanding Voltage for Primary to secondary |
Primary to secondary |
4242 |
VDC |
|
Dielectric Withstanding Voltage for Primary to Ground |
Primary to ground |
2121 |
VDC |
|
Isolation Resistance |
Test Voltage = 2100VDC |
50 |
MΩ |
|
EMI requirements for CISPR-11 |
Vin=220VAC |
B |
CLASS |
|
EMI requirements for FCC PART-18 |
Vin=110VAC |
B |
CLASS |
|
Safety UL/c-UL, TUV/T-mark, FCC, CE |
UL 60950-1, EN 60950-1 |
n/a |
n/a |
|
Environmental |
RoHS compliant |
n/a |
n/a |
|
Mechanical and PIN out |
|
PIN CHART
|
Note:
|
||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||